AUX air conditioner service manual
The sleeping process under cooling mode:
Setting temperature
rises another 1℃
rises 1℃
39
Previous Setting
temperature
1h 2h 7h(end sleeping process,turn off)
The sleeping process under heating mode:
Setting temperature
Previous setting falls 2℃
temperature
Falls another 2℃
1h 2h 7h(end sleeping process,turn off)
Timing control function⑾
①The longest Timing time is 24 hour and to be counted per minute, single timing method,
the timing function will not be cancelled due to the modes changed, and the timing indication
light on after completing the timing setting.
②Timing power-off:The timing power-off function can be set only under the working condition of
the air-conditioner. The timing range is 1min-24h,and the air-conditioner turns off automatically once
the time is over.
③Timing power-on:The timing power-on function can be set only under the working condition of the
air-conditioner. The timing range is 1min-24h,and the air-conditioner turns on automatically once
reaching the time.
④The restart and power-off motions happen after completion of the Timing setting will cause the
automatic cancellation of the previous timing and sleeping setting function.
Self⑿ -detecting function
Press the Emergency button and electrify the air-conditioner, the self-detecting process starts
after twice short buzz from buzzer:
Start the electric heating, run the indoor fan at a high fan speed, open the air door to be the
maximum Æthe digital display and three indicating light on in 1 secondÆ digital displays
“11”、“22”、“33”、“44” in turn and 1second for each of them ÆRun light on 1 second ÆTimer