AUX air conditioner service manual
35
Ventilation mode
Under ventilation mode, the outdoor unit is always off, and the indoor fan runs according to the
default wind-speed. The remote control can be set with three types wind-speed, e.g. high fan, low fan
and silent fan except the strong fan; The operation condition of the air door is same as the one under
the refrigeration mode; The mode includes the function of timing, auto-restart (optional), negative ion
(optional), I feeloptional.
Heating mode
The default temperature is determined by the remote control and to be within the range of 16 - 32 ,
which can be adjusted by the button of “+” and “-”. Press the button of “fan speed selection” for
choosing the wind speed from the four gears of strong fan, high fan, low fan and mute fan. The other
conditions are as following, when:
TA-3-TS-1℃,if after three minutes delay time as for protection purpose, the compressor and the
outdoor fan start, the indoor fan works in cold-wind prevention condition, the TA shown on the digital
display has 3 temperature compensation.
TA-3-TS1℃,if the compressor last continuously running for 3minutes, the compressor and the
outdoor fan stop, the indoor fan keeps on working under anti cold-wind condition. The TA shown on
the digital display has 3 temperature compensation.
TA-3=TSretain the previous status
Automatic wind speed control, when:
TA TSwind speed in high fan
TS TATS +2℃,wind speed in middle fan
TA TS + 2℃,wind speed in low fan
When wind speed turns from the low fan to high fan without 3 minutes protection delay; wind speed
turns from the high fan to low fan with 3 minutes protection delay
When the heating process is ongoing, the button of the “Swing” can control and stop the swing
leaves; When swing works freely, the maximum angle of the swing leaves is 50°e.g. the swinging
status between 3-5 (refer to picture 3);
There is no 3 minutes’ delay protection for electrifying the compressor initially. The compressor
starts 10 seconds later after the start of the four-way valve. The outdoor fan starts 2 seconds later after
the start of the compressor; Low down TS to be TA-3then the compressor turns off immediately
without the restriction condition of 3 minutes protection delay;
The mode includes the functions of timing, sleeping, auto -restart (optional), negative ion (optional),
I feeloptional
The four-way valve starts immediately once being electrified.10 seconds later the compressor starts;
Under the compressor opening condition, the four-way valve shuts off after 2 minutes and 50 seconds
delay protection when turn off or switch the controller; The four-way valve turns off immediately after
turning off the controller when the compressor is off;