Job Aid
The following table shows the environmental requirements for the Ethernet Routing Switch
5600.
Table 5: Job aid: Ethernet Routing Switch 5600 Series environmental requirements
Storage temperature -40° to 85°C
Operating temperature 0° to 50°C (continuous operational.) 0° to
55°C (short term operational)
ESS temperature -5° to 55°C
Operating relative humidity 10 to 90% non-condensing
Storage relative humidity 10 to 95% non-condensing
Operating altitude 13,000 feet above sea level
Storage altitude -1,000 to 40,000 feet above sea level
Cooling Dependent on system requirements
Audible noise 45dB to 55dB nominal
DMT temperature -10° to 60°C
DVT temperature -15° to 65°C
Miscellaneous Operating Considerations
• No heat sources such as hot air vents or
direct sunlight located near the switch.
• No sources of severe electromagnetic
interference located near the switch.
• No excessive dust in the environment.
• An adequate power source is located
within 6 feet (1.83 meters) of the switch.
One 15-amp circuit is required for each
power supply.
• At least 2 inches (5.08 centimeters) of
clearance on each side of the switch unit
for ventilation.
• Adequate clearance is allotted at the front
and rear of the switch for access to
cables.
Procedures for installation of the switch
44 Installing Avaya Ethernet Routing Switch 5000 Series December 2013