Setting non-base units using the UI/Mode Select button
About this task
This procedure describes the steps necessary to set a non-base unit using the UI button.
Note:
The UI button is labeled Mode Select on Avaya branded equipment.
Procedure
1. Press and hold the UI button for three seconds. The unit is now in configuration
mode. The color and status of the Status LED turns to blinking green.
2. Press the UI button twice. The Base LED will turn off and the Up and Down LEDs
are turned off.
3. Press and hold the UI button for three seconds to confirm the commands. The
Status LED returns to a steady green state to confirm command acceptance. If the
command is rejected, the Status LED moves to a blinking amber state.
Resetting a stack using the UI/Mode Select button
About this task
The following procedure describes the steps to reset the stack using the UI button.
Note:
The UI button is labeled Mode Select on Avaya branded equipment.
Procedure
1. Press and hold the UI button for three seconds.
The unit is now in configuration mode. The color and status of the Status LED turns
to blinking green.
2. Press the UI button three times.
The Base, Up, and Down LEDs will move to a blinking amber state and blink in
unison.
3. Press and hold the UI button for three seconds to confirm the command.
Stack configuration