BCM50 System Start Up
34 NN40010-318 Issue 1.2 BCM50 Rls 6.0
7. Also ensure that the correct Time Zone is selected.
Date & Time Settings
NTP: Set to NTP (Network Time Protocol) if the system uses
a network server to determine the correct time and date.
Trunk: Set to Trunk to use time and date settings from a CO
through an analog or IDSN line.
Manual: Set to Manual if you want to be able to manually
configure the time and date for your system.
Default: Manual
If Date and Time Source is set to NTP, then enter an
address for the server.
The number of seconds between synchronization with the
NTP server.
Select whether the NTP security mode is secured or
unsecured.
Raise alarm if clock
differs by at least
(s)
The number of discrepancy seconds specified that must
occur before the system notifies you of a time difference
between the BCM time and the NTP server, if the system
automatically checks with the NTP server.
ID for accessing the NTP server.
Control key corresponding to ID for accessing the NTP
server
Use the dropdown calendar to select the correct date and
time.
Select the time zone for this system.
Setting the Start DN and Telephony Region
Use the following procedure to set your first extension number, telephony
template, and telephony region.
1. From the Administration tab, double-click the Utilities folder to
expand it.
2. Select Reset from the Utilities folder.