MDF connections
1. Punch down the following wires at the MDF. See Table 1-8.
Table 1-8. 110 block cross-connect pins
SRP Aux EPN Aux
Color
a
a. The following wire colors apply to this table:
W = White, BL = Blue, O = Orange, G = Green,
BR = Brown, BK = Black, V = Violet
Cross-
Connect
Pin
Number
Cross-
Connect
Pin
Number Color
G-V 46 3 W-O
SRP Aux SRP Switch
Color
Cross-
Connect
Pin
Number
Cross-
Connect
Pin
Number Color
W-O 3 46 G-V
V-G 45 23 BK-O
EPN Aux SRP Switch
Color
Cross-
Connect
Pin
Number
Cross-
Connect
Pin
Number Color
O-W 4 24 O-BK
W-G 5 47 V-BR
W-BR 7 48 BR-V
V-BL 41 41 V-BL
BL-V 42 42 BL-V
V-G 45 43 V-O
G-V 46 44 O-V