DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Maintenance
2-23Maintenance procedure
2
Post-reset check
Check to see that the following conditions are met before leaving the customer
premises:
1. The EI circuit pack in the SRP should be fast flashing.
This is appropriate
for Normal mode
, because the links are connected from the SREPN to the
Release 9r. Figure 2-16 shows the SREPN EI board test results.
Figure 2-16. Test fiber-link screen (SRP)
These Fail and Abort results are appropriate for Normal mode.
2. After normal service is returned to the SREPN, the SRP is in an
alarmed
state
. This is
normal
for the SRP and indicates that the TN2301 has
disconnected from the SREPN, and the SRP is no longer in control.
Connections are re-established between the EI in the SREPN and its EI/
SNI counterpart in the Release 9r PPN, and the system is now in its
original Release 9r-EI configuration.
Power alarms
Carrier power failure
A carrier power failure generates a MAJOR alarm against the CARR-POW
Maintenance Object. This condition is evident by:
A CARR-POW alarm in the Alarm or Error logs on the R9si system (SRP).
The LEDs in the SRP cabinet are all dark except for the yellow LED on the
TN2301 circuit pack.
test fiber-link Page 1 SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A01 EXP-INTF 237 FAIL
01A01 EXP-INTF 238 FAIL
01A01 EXP-INTF 240 FAIL 1032
01A01 EXP-INTF 241 ABORT 1033
01A01 EXP-INTF 589 ABORT 1033
01A01 EXP-INTF 316 PASS