DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Maintenance
2-15Maintenance procedure
2
NOTE:
In an EPN the TN775C EPN Maintenance circuit pack monitors the sanity of
the Expansion Interface circuit pack. If the EI circuit pack should cycle
between sane and insane several times, the Maintenance circuit pack holds
the EI circuit pack reset.
If a new Expansion Interface circuit pack is installed in the EPN and
the red LED stays on, remove the EPN Maintenance circuit pack
because it may be holding the new EI circuit pack reset.
This can happen when there is a link problem to the EPN, and the
EPN restarts several times.
Reinstall the maintenance circuit pack after the Expansion Interface
circuit pack is physically inserted and the EI circuit pack’s red LED is
off.
Which EPN is survivable?
1. On the Release 9r system, type the list cabinet command and press Enter.
Determine which EPN is “watched” by Survivable Remote equipment by
looking for the lower-case “s” before the letters “EPN” in the Type field as
shown in Figure 2-8.
Figure 2-8. List cabinet screen (Release 9r)
2. Once you have located the physical equipment, check to see whether the
Red SURVIVE MODE ON LED is on, indicating that the system is in
Survive Mode.
list cabinet SPE B
CABINET REPORT
No. Type Layout Room Floor Building A B C D E
1 PPN 5-car CS_1 1 ABC_DE PN 01 PN 01 PN 01 PN 01 SN 01
2 sEPN 5-car CS_1 1 ABC_DE PN 02 PN 02 PN 02 PN 02 PN 02