DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Maintenance
2-42Restore from remote location
2
The Table 2-13 describes the conditions in which the restore from a remote
location is possible.
Table 2-13. TN2301 switch configuration based on input
Inputs to Control Logic Modes
Remote
restore
Survive
mode
requested
a
a. The EPN Maintenance (TN775C) circuit pack requests switching to Survive mode.
Switch
position
SRP
power State of SREPN
Not active Not active AUTO Good Normal mode: EPN connected with Release 9r
PPN
Not active Active AUTO Good Survive mode: EPN connected to SRP
Not active Does not
matter
TEST Good Survive mode: EPN connected to SRP
Active Does not
matter
TEST Good Survive mode: EPN connected to SRP
Not active Does not
matter
RSTR Good Normal mode: EPN connected to Release 9r
PPN
Not active Does not
matter
RSTR Bad Normal mode: EPN connected with Release 9r
PPN
Active Does not
matter
AUTO or
RSTR
Good Normal mode: EPN connected to Release 9r
PPN
Continued on next page