Release Notes for Avaya Scopia® XT Series Known Issues | 36
Known Issues
Avaya performs effective testing of each software version. Patch software may be available to fix
known issues of this software version. Please contact Avaya’s Customer Support Service for
further information.
This section details the list of known issues for this version. Issues are common to Avaya XT
Series.
Table 7: List of known issues in this version
Category
Case Number/
Ticket ID
Description of issue
Solution/Workaround
System Setup
Echo cancellation issue when
audio out of HD2 is enabled
(HD2 is connected to a track of
the XT audio mixer) and HD2
audio output is heard in the
room through loudspeakers or a
monitor.
In Configure > Advanced > I/O Connections > Audio
Outputs > Tracks > Outputs from tracks: Set HD2
to Off.
Echo cancellation issue when
using HD2 as single monitor
Connect the single monitor to HD1. HD2 should be
used only as additional monitor.
Some HD monitors crop the
output.
If the borders of the graphical menus are not fully
visible, select Configure > Quick Setup from the
Main menu. Select Next in the Quick Setup to adjust
how the menu is displayed in the monitor. You can
also resize the local and received presentation on
the additional monitor from the web interface.
Select Administrator Settings > I/O Connections >
Monitor > Graphical Adjustments.
Additional monitor/Cloned
monitor may become black
during the call
It is strongly suggested to use two monitors of the
same Vendor/Brand/Model, with the same settings.
In particular, do not mix 1080p/720p monitors-.
During a call, do not change monitor resolutions
and do not connect/disconnect monitors
QC#12897
Placing the camera on top of the
system may cause the system to
overheat and reset.
Place the camera near the system.
QC#20476
SI #161693: [Executive] During
the XT Control app installation
(using Internet Explorer)
appears a security warning
about an 'unknown' publisher.
The warning appears because the XT Control
application is not signed: continue with the
installation since the content is not harmful for the
PC.
Recovery Mode
In Recovery Mode, only lower
slot can be used to plug an USB
key for software upgrade
RVXT5000-1118
Sometimes the system displays
black video when forced to start
in recovery mode
Disconnect and reconnect XT power supply
QC#11258
QC#25349
In Recovery Mode, you can only
use HD1 monitor and Ethernet
cable connected to GLAN1. A
message 'Starting System…'
appears for about 50 seconds at
system start up.
I/O Connections
XT4300
The camera does not turn on
the standby led when the codec
unit is in power off
Cascade cameras
Cannot change camera cascade
driver mode or
connect/disconnect/change
cascaded camera order on the
fly.
Changing camera driver mode from automatic to
manual and the reverse, or changing the camera
cascade setup requires following a specific
procedure: see below.
In I/O Connections>Cameras>General, select Driver
mode as Automatic if all the cascaded cameras are
of the same model. Otherwise, select Manual and