03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
78
5. Connect the internal cable to connector
CN701 on the CPU board [6].
6. Attach respectively close the rear hood.
7. Plug in the remote operator panel.
Switchon the machine.
8. Operate the printer using the remote
operator panel. Print a service status
printout (PRINT INFO > Service status).
The service printout must show the
firmware versions of both operator
panels [7].
CAUTION!
Manipulating both operator panels
simultaneously can cause
malfunctions.
Always use only one operator
panel at a time to operate the
printer (Using both operator
panels alternately is admissible).
CAUTION!
If the connection cable is longer than
2.5m, EMC-caused disturbances can
occur.
Only use the factory-installed
cable.