EasyManuals Logo

Avery Weigh-Tronix E1010 User Manual

Avery Weigh-Tronix E1010
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11
Model E1010 Indicator User’s Manual
The accumulator is memory that collects individual weighments (gross and
net) and stores the totals. These totals can be recalled at any time and the
number of weighments included in the totals can be displayed. With the
proper password all information can be deleted. See the Service Manual.
The accumulator maximum is 999,999. It does not rollover and start over at
0.
To use the accumulator, power up the unit and follow these steps:
1. Empty the scale and press the ZERO key to zero the display. . .
0 is displayed and gross and center of zero annunciators are lit.
2. Place item on the scale. . .
Weight is displayed.
3. You can press the PRINT or F1 key to add weight to the accumulator. If
you press PRINT, the weight is accumulated and the information
printed. If you press F1, the weight is accumulated. Scale weight must
return to zero before another weighment can be accumulated.
4. Repeat 2 and 3 for each weighment you want to accumulate.
5. To review the accumulator total and the number of weighments, remove
all weight from the scale and press the SELECT key repeatedly. . .
1st press = Net weight displayed
2nd press = Tare weight displayed
3rd press = Gross total of all weighments is displayed
4th press = Net total of all weighments is displayed
5th press = Number of weighments is displayed
6th press = Display returns to gross weigh mode
You need the supervisor’s password to clear the accumulator. See the
Service Manual for instructions.
Accumulator
Weighing
Press the MODE key to scroll
through the enabled applica-
tions.
You can use tare/net weighing
with the accumulator applica-
tion. The accumulator stores
both gross and net totals for
later recall.
You can use the cutoff (or trips) function if so desired while in the Accumula-
tor application. The output will turn on when weight goes above the target
set for that output and will remain on until the weight falls below the target.
Follow these steps to set up to three outputs:
1. With the indicator powered up, press and hold the F1 key until. . .
OP1 is displayed.
2. Press the PRINT key to set the value for the output. . .
Key in a value and press the F1 key to accept the value. OP1 will
be displayed.
You can scroll through all three outputs by using the TARE and
UNITS keys.
3. Press the UNITS key. . .
OP2 is displayed.
4. Repeat steps 2 and 3 for each output. Press ESC key to return to
normal operation with the ingredients active. Indicator will automatically
return to normal weighing mode after OP3 value is entered.
Using Cutoffs

Other manuals for Avery Weigh-Tronix E1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix E1010 and is the answer not in the manual?

Avery Weigh-Tronix E1010 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelE1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals