4
Model E1010 Indicator User’s Manual
Specifications
Power requirements
100-240 Volts AC @ 600 mA
50/60 Hz
Internal battery: 23 hours of continuous operation
with one weight sensor; 15 hours of continuous
operation with four weight sensors
Standby mode extends battery life
Excitation
5 volts
Supports up to four 350-ohm weight sensors
Analog signal input range
+/- 12 mV/V
Analog input sensitivity
0.2 µV/divisions minimum
1.0 µV/divisions recommended
Calibration
2 to 5 points stored
Operational keys
Tare, Select, Zero, Print, Units, F1, Clear, Mode,
Escape, Enter, On/Off, 0-9 numeric and decimal
point
Operational annunciators
Center of Zero, Motion, Gross, Tare, Net, Battery
status
Under/Target/Over
Units of measure (LB, KG)
Peak, Print, OP1, OP2, OP3
Display
Seven-digit, seven-segment, 0. 8-inch high
Lighted STN Transmissive
Display rate Selectable (1, 2, 5, 10)
Analog to digital conversion rate
60 times per second
Unit of measure:
Three, independently programmable
Pounds, Kilograms, Custom
Capacity selections
999,999 with decimal located from zero to five
places
Incremental selections
Multiples and sub-multiples of 1, 2, 5
Programmable selections
Zero range, motion detection, automatic zero
tracking, five-point linearization
Time and date / RAM
Battery backed up real time clock and RAM
Internal resolution
41,248,140 counts per mV/V per sec
Standard inputs
Three logic level inputs for: Zero, Print, Tare,
Units, F1
Standard outputs
Three cutoff outputs, open collector design
Serial port RS-232 or 20mA current loop, or RS-
422 or RS-485
Serial Command Inputs
Programmable serial response to ASCII character
input, SMA protocol
Self diagnostics
Display, keys, inputs, outputs, serial port
Circuitry protection
RFI, EMI, and ESD protection
Options
Trips Interface Unit (TIU3)
Operating applications
General weighing, Simple counting,
Check weighing,
Peak measurement, Batching, Remote display
Operating temperature
14 to 104° F (-10 to 40° C) approved
-4 to 140° F (-20 to 60° C) non-legal
10 to 90% noncondensing humidity
Enclosure
Stainless steel NEMA 6/4X
Dimensions:
9.25” W x 9.25” H x4.5 “ D
(23.5cm W x 23.5cm H x 11.4cm D)
(without mounting bracket)
9.75" W x 11” H x 7" D
(24.8cm W x 28cm H x 17.8cm D)
(with mounting bracket)
Weight: 11 lb, 5 kg
Agencies:
NTEP CC# 04-029
Class III/IIIL:10,000 divisions
OIML Cert. No. R76/1992-GB1-04.09
Class III: 10,000 divisions
Canadian Weights and Measures pending
UL/CUL
CE marked

Other manuals for Avery Weigh-Tronix E1010