Counting
This section applies if your indicator has the counting application active.
Applications are activated through a password protected menu. See the
Service Manual for instructions.
Follow these steps to perform a counting function with the E1010:
1. In gross weight mode, press the F1 key. . .
PCS is displayed followed by an underscore cursor.
2. Enter the sample size you desire (see note at left) and press ENTER. . .
Add X is displayed. X is the sample size you keyed in.
3. Place the correct number of parts on the scale and press the ENTER
key. BUSY is briefly displayed, followed by one of two possible displays:
a. If the sample met the minimum sample requirements, the
display will show the correct number of parts on the scale.
b. If the sample size was not large enough, the display will tell
you how many more parts to add to the scale (For example: 5
might be displayed.) Add the number requested, wait for the
scale to stabilize, then press ENTER again. The display will
read the correct number of parts on the scale.
4. Place the parts on the scale to be counted.
You can use the cutoff (or trips) function if so desired while in the counting
application. Follow these steps to set up to three outputs:
1. With the indicator powered up, press and hold the F1 key until. . .
OP1 is displayed.
2. Press the PRINT key to set the value for the output. . .
Key in a value and press the F1 key to accept the value. OP1 will
be displayed.
You can scroll through all three outputs by using the TARE and
UNITS keys.
3. Press the UNITS key. . .
OP2 is displayed.
4. Repeat steps 2 and 3 for each output. Press ESC key to return to
normal operation with the ingredients active. Indicator will automatically
return to normal weighing mode after OP3 value is entered.
Using Cutoffs
This indicator has a 10 channel
PLU (Product Look Up)
memory. To access a memory
channel, press a number from
0 to 9, then press the F1 key.