EN31EN 30
• Press PROG again for 3 seconds. L0 will flash
twice, L1 will turn on and you will be in menu 2
(advanced settings).
• Press PROG again for 3 seconds. L0 will flash three
times, L1 will turn on and you will be in menu 3
(advanced settings).
3.2 - ADVANCED SETTINGS MENU (MENU 2)
Accélération
OK PROG
Réglage accélération
+ : augmente l’accération
– : diminue l’accélération
OK
MENU 0
réglable de 0 à 4
Tolérance butée
OK
PROG
Réglage tolérance
+ : augmente la tolérance
– : diminue la tolérance
OK
MENU 0
réglable de 0 à 4
* cette modification nécessite de refaire un auto-apprentissage
Type de portailMode photocellules
OK PROG
Type de portail
– et + pour régler la valeur
OK
MENU 0
OK PROG
Mode photocellules
– et + pour régler la valeur
OK
MENU 0
0 : inactives en début d’ouverture
(par défaut)
1 : actives en début d’ouverture
0 : portail à 2 battants (par
défaut)
1 : portail à 1 battant (portillon)
–
+
+
–
+
–
L1 L2 L3 L4
L1 L2 L3 L4
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
L1 L2
L3 L4
L1
L2 L3 L4
L1 L2 L3 L4
Enregistre réglage*
L1 L2 L3 L4
Enregistre réglage
L1 L2 L3 L4
Enregistre réglage*
L1 L2 L3 L4
Enregistre réglage*
L1 L2 L3 L4
This change requires a new self-learning procedure.
3.2.1 - ACCELERATION
The acceleration at the start of the panel opening
process can be adjusted from a level of 0 to 4. The
higher this value, the more time the gate will take
to reach its nominal speed. The default level is 3,
at which the gate takes about 4 seconds to open.
It may be useful to reduce the acceleration for a
softer start.
To adjust the acceleration, follow the
procedure below
• Press PROG for 3 seconds. L0 will flash once and
L1 will turn on.
• Press
PROG for 3 seconds. L0 will flash twice.
• Press OK and the number of LEDs that turn on will
indicate the set value.
• Use the “+” and “-” buttons to change this value.
• Press OK to confirm this value. All the LEDs will
turn on and off to confirm the operation.
NOTE: If the acceleration setting is changed, self-
learning must be repeated.
3.2.2 - PHOTOCELL MODE
The photocells are active when the panels close
because they are placed between the posts (pair 1)
to secure the passage between panels.
The installation of a second set of photocells is
useful to completely protect the gate movement
area during closing and opening:
D - BEGINNING OPERATION