5.1 - OBSTACLE DETECTION
During their movement, the panels may encounter
an obstacle.
For safety purposes, if the motors are under too
much strain (the force is adjustable; see “Motor
Force” in the settings), the gate stops and releases
the pressure and the flashing light emits double
flashes for 30 seconds unless a command is
activated.
On activating a command (the same one that was
used to start the movement), the gate starts to
move in the opposite direction.
If the gate has a large area of wind resistance,
this can trigger obstacle detection in windy
weather. In this case, increasing the motor force
is recommended.
6 - MANUAL MOVEMENT
In order to manually manoeuvre the gate, just remove
the pin from the gate mounting bracket and remove
the pin to disengage the operator arm. The gate can
then be opened manually.
Warning: When the motors are disengaged, the
gate may be set in motion by the wind or an
external push. It is therefore important to be
careful or block the gate to avoid any risk of
injury.
Just remove the pin and raise the operator arm. The
gate can therefore be opened manually during a
power failure.