There are two types of code: Error (E) or Information (I). N.B. an error requires action from the installer to
correct the motor drive problem.
L1 L2 L3 L4 MEANING TYPE
An obstacle has been detected in M1 when closing. I
An obstacle has been detected in M2 when closing. I
The photocell beam has been obstructed. I
An obstacle has been detected in M1 when opening. I
An obstacle has been detected in M2 when opening. I
Motor M1 is not connected or incorrectly connected
(contact failure). Check connections.
E
Motor M2 is not connected or incorrectly connected
(contact failure). Check connections.
E
The maximum operating time has been reached (a
motor is idle and the stop has not been reached?).
Check that the motor is engaged.
E
Panel M1 closed before panel M2. Increase the time
interval between the movement of both panels.
E
Three obstacles detected in a row during opening.
Check the gate movement area.
E
Three obstacles detected in a row during closing.
Check the gate movement area.
E
The main power supply has been cut during a
movement phase OR the battery is too weak for
proper operation.
E
Self-learning is not valid (it was never performed or
a setting that requires repetition of self-learning has
been changed). Start self-learning.
E
Automatic closure has been cancelled. Generated if
the gate re-opens 3 times (10 in collective mode) after
a photocell has been obstructed during automatic
closure OR if the beam was obstructed for more than
3 minutes.
E
The gate control input (2B) is permanently earthed.
Check the connections.
E