4
4.4 Electrical connection with the
magnetic vibrator
An operating manual with connection diagram (part of the operating manual) is
included with each VIBTRONIC controller.
F
Make all connections between mains, controller, command-value circuit and
magnetic vibrator.
F
Note any device-type peculiarities as they relate to the available options and
observe the relevant terminal assignments shown earlier as well as the con-
nection diagram.
When connected to mains, dangerously high voltages are present inside the con-
troller. Touching electrically live components can be lethal! Before switching on
mains power, ensure that no live parts can be touched. Close the cover of the con-
trol box or the control cabinet door(s)!
4.4.1 Electromagnetic Compatibility (EMC)
The series SC(E)…-2 controllers were developed and constructed in conformance
with EMC directive 89/336/EWG. They fulfil the requirements of standards EN
50081-2 and EN 50082-2.
The controllers are designed in accordance with EN 50081-2 (RFI-emission) for
industrial areas and must not be used in residential areas or business districts.
Observe the information regarding the shielding of signal lines described in the
preceding chapters on terminal assignment!