Operation
48
F-FEM-CNT — User’s Guide
4.4.4
Add-on Connection: X24, X25
NOTICE
Only prefabricated AVL cables may be used at the connectors X24 and X25.
Fig. 31 Add-on connection: X24, X25
Pin Signal at X24 Signal at X25
1SLCK+ SLCK+
2SCLK– SCLK–
3PL1+ PL2+
4PL1– PL2–
5nc nc
6SDO1+ SDO2+
7SDO1– SDO2–
8SDI1+ SDI2+
9SDI1– SDI2–
10 WDOG_NO (24 V) WDOG_NO (24 V)
11 DGND DGND
12 GND_24 GND_24
13 + 24 V + 24 V
14 + 24 V + 24 V
15 GND_24 GND_24
Case Shielding Shielding
Tab. 9 Pin assignment