AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
-Locked=RelayclosedSelectforlocksthatunlockduringpoweroutages(failopen/safe).
NoneSelectifonlyonelockwillbeused.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
Motorizedlocksmustbeconguredassecondarylocks.
Readers
1.Ifareaderwillbeused,selectReaderandthenselecttheoptionsthatmatchthereader’scommunicationprotocol.
2.Ifarequesttoexit(REX)devicesuchasabutton,sensor,orpushbarwillbeused,selectREXandthenselecttheoption
thatmatcheshowtheREXdevice’scircuitswillbeconnected.
Ifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor,selectRequiremanualunlock.
3.IfconnectingmorethanonereaderorREXdevicetothedoorcontroller,dotheprevioustwostepsagainuntileach
readerorREXdevicehasthecorrectsettings.
Thefollowingoptionsforreadersareavailable:
WiegandSelectforreadersthatuseWiegandprotocols.
RS485halfduplexSelectforRS485readerswithhalfduplexsupportandthenselecttheRS485protocolthatis
supportedbythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
RS485fullduplexSelectforRS485readerswithfullduplexsupportandthenselecttheRS485protocolthatissupported
bythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
ThefollowingoptionsforREXdevicesareavailable:
ActivelowSelectifactivatingtheREXdeviceclosesthecircuit.
ActivehighSelectifactivatingtheREXdeviceopensthecircuit.
RequiremanualunlockSelectifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor.The
doorforcedopenalarmwillnotbetriggeredaslongastheuseropensthedoorwithintheaccesstime.Deselectifthedoor
shallunlockautomaticallywhentheuseractivatestheREXdevice.
Important
Ifthedoorcontrollerhasonlybeenconguredwithonedoorbeforeitisupgradedtormware1.15orlaterfromrmware
1.10,Requiremanualunlockwillbenon-selectableatrst.TomakeRequiremanualunlockselectable,gotoSetup>
HardwareCongurationandclickResetandstartanewhardwareconguration.Thensetuptherulesforthedoors
connectedtothedoorcontrollerandaddthemtogroups,seeDoors.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
VerifytheHardwareConnections
Whenthehardwareinstallationandcongurationiscomplete,andanytimeduringthedoorcontroller’slifetime,youcanverifythe
functionoftheconnecteddoormonitors,locksandreaders.
Toverifythecongurationandaccessthevericationcontrols,gotoSetup>HardwareConnectionVerication.
VericationControls
Doorstate–Verifythecurrentstateofthedoormonitor,dooralarmsandlocks.ClickGetcurrentstate.
13

Other manuals for Axis A1001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axis A1001 and is the answer not in the manual?

Axis A1001 Specifications

General IconGeneral
InterfaceRS-485
Built-in UPS-
Maximum number of doors2 door(s)
DC voltage range10 - 30 V
Power consumption (typical)26 W
Weight and Dimensions IconWeight and Dimensions
Depth45.3 mm
Width180 mm
Weight500 g