EasyManua.ls Logo

Axis A1001 - Page 49

Axis A1001
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXISA1001NetworkDoorController&AXISEntryManager
TechnicalSpecications
ReaderDataConnector
6-pinterminalblocksupportingRS485andWiegandprotocolsforcommunicationwiththe
reader.
TheRS485portssupport:
•Two-wireRS485halfduplex
•Four-wireRS485fullduplex
TheWiegandportssupport:
•Two-wireWiegand
FunctionPinNotes
B-
1
RS485
A+
2
ForfullduplexRS485
ForhalfduplexRS485
B-
3
RS485
A+
4
ForfullduplexRS485
ForhalfduplexRS485
Data0
5
Wiegand
Data1
6
ForWiegand
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
ReaderI/OConnector
6-pinterminalblockfor:
•Auxiliarypower(DCoutput)
•DigitalInput
•DigitalOutput
•0VDC(-)
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
DCoutput
2
Forpoweringauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
12VDC
Maxload=300mA
Digitalinput—Connecttopin1toactivate,orleave
oating(unconnected)todeactivate.
0tomax40VDC
Congurable(Input
orOutput)
3–6
Digitaloutput—Connecttopin1toactivate,orleave
oating(unconnected)todeactivate.Ifusedwithan
inductiveload,e.g.arelay,adiodemustbeconnected
inparallelwiththeload,forprotectionagainstvoltage
transients.
0tomax40VDC,opendrain,
100mA
DoorConnector
Two4-pinterminalblocksfordoormonitoringdevices(digitalinput).
49