AXISA1601NetworkDoorController
Systemconfiguration
Howtore-congureSmartIntego
1.ClickSetupinthetopmenu.
2.ClickCongureServices>Settings.
3.ClickRe-congure.
4.ClickBrowse...,selectthecsv-leandclickUploadle.
5.SelectaGatewayNodeandclickNext.
6.Apreviewofthenewcongurationisshown.Disablethedoormonitorsifneeded.
Note
ThedoormonitorsettingscomefromtheimportedCSVle.Youshouldn'tneedtochangethissettinginanormalinstallation.
7.ClickCongure.
8.Anoverviewofthedoorsincludedinthecongurationisshown.ClickSettingstocongureeachdoorindividually.
MaintenanceInstructions
Tokeeptheaccesscontrolsystemrunningsmoothly,Axisrecommendsregularmaintenanceoftheaccesscontrolsystem,including
doorcontrollersandconnecteddevices.
Domaintenanceatleastonceayear.Thesuggestedmaintenanceprocedureincludes,butisnotlimitedto,thefollowingsteps:
•Makesurealltheconnectionsbetweenthedoorcontrollerandtheexternaldevicesaresecure.
•Verifyallthehardwareconnections.SeeVericationControlsDoorsonpage16.
•Verifythatthesystem,includingtheconnectedexternaldevices,functionscorrectly.
-Swipeacardandtestthereaders,doors,andlocks.
-IfthesystemincludesREXdevices,sensorsorotherdevices,testthemaswell.
-Ifactivated,testthetamperingalarms.
Iftheresultsfromanyofthestepsaboveindicatefaultsorunexpectedbehavior:
-Testthesignalsofthewiresusingappropriateequipmentandcheckifthewiresorcablesaredamaged
inanyway.
-Replacealldamagedorfaultycablesandwires.
-Oncethecablesandwireshavebeenreplaced,verifyallthehardwareconnectionsagain.SeeVerication
ControlsDoorsonpage16.
•Ifthedoorcontrollerisnotbehavingasexpected,seeTroubleshootingonpage33andMaintenanceonpage31for
moreinformation.
20