AXISA1601NetworkDoorController
Systemconfiguration
Systemconfiguration
Toopentheproduct’ssetuppages,clickSetupinthetopright-handcorneroftheOverviewpage.
TheAxisproductcanbeconguredbyadministrators.Formoreinformationaboutusersandadministrators,seepage25.
Conguration–stepbystep
Beforeyoustartusingtheaccesscontrolsystem,youshouldcompletethefollowingsetupsteps:
1.IfEnglishisnotyourrstlanguage,youmaywanttheproduct’swebpagetouseadifferentlanguage.SeeSelecta
languageonpage9.
2.Setthedateandtime.Seepage9.
3.Congurethenetworksettings.Seepage10.
4.Congurethedoorcontrollerandconnecteddevicessuchasreaders,locksandrequesttoexit(REX)devices.SeeCongure
thehardwareonpage10.
5.VerifytheHardwareConnections.Seepage16.
6.Congurecardsandformats.Seepage17.
Forinformationaboutmaintenancerecommendations,seeMaintenanceInstructionsonpage20.
Selectalanguage
Thedefaultlanguageoftheproduct’swebpageisEnglish,butyoucanswitchtoanyofthelanguagesthatareincludedinthe
product’srmware.Forinformationaboutthelatestavailablermware,seewww.axis.com
Youcanswitchlanguagesinanyoftheproduct’swebpages.
Toswitchlanguages,clickthelanguagedrop-downlist
andselectalanguage.Alltheproduct’swebpagesandhelppagesare
displayedintheselectedlanguage.
Note
•Whenyouswitchlanguages,thedateformatalsochangestoaformatcommonlyusedintheselectedlanguage.The
correctformatisdisplayedinthedataelds.
•Ifyouresettheproducttofactorydefaultsettings,theproduct’swebpageswitchesbacktoEnglish.
•Ifyourestoreorrestarttheproduct,orupgradethermware,theproduct’swebpagewillcontinuetousetheselected
language.
SettheDateandTime
TosetthedateandtimeoftheAxisproduct,gotoSetup>Date&Time.
Youcansetthedateandtimeinthefollowingways:
•Getthedateandtimefromanetworktimeprotocol(NTP)server.Seepage10.
•Setthedateandtimemanually.Seepage10.
•Getthedateandtimefromthecomputer.Seepage10.
Currentcontrollertimedisplaysthedoorcontroller’scurrentdateandtime(24hclock).
9