AXISA1601NetworkDoorController
Eventconfiguration
Thetablebelowshowstheeventsthatarepreconguredinthedoorcontrollertotriggerreaderfeedbackandtheirtypicalreader
feedbacksignals.FeedbacksignalsforAXISreadersarepresentedintheInstallationGuidesuppliedwiththeAXISreader.
EventWiegand
dualLED
Wiegand
singleLED
OSDP
Beeperpattern
State
Idle
1
Off
RedRed
Silent
Normal
RequirePIN
Flashingred/greenFlashingred/greenFlashingred/green
TwoshortbeepsPINrequired
AccessGrantedGreenGreenGreen
BeepAccessgranted
AccessDeniedRedRedRedBeepAccessdenied
1.Idlestateisenteredwhenthedoorisclosedandthelockislocked.
Feedbackmessagesotherthantheabovemustbeconguredbyaclientsuchasanaccessmanagementsystem,throughtheVAPIX®
applicationprogramminginterface,thatsupportsthisfeatureandusereadersthatcanprovidetherequiredsignals.Formore
information,seetheuserinformationsuppliedbytheaccessmanagementsystemdeveloperandreadermanufacturer.