1. Use the control knob/push button to select
the energy icon.
2. Click to change to the setting level.
3. Use the control knob/push button to select
the required power type.
4. Click the control knob/push button to
confirm the value.
SYMBOL OPERATING MODE POWER TYPE
a LP gas LP gas
b MIX 1 * Electricity 850W + Gas
c MIX 2 * Electricity 1700W+ Gas
d EL 1 * Electricity 850W
e EL 2 * Electricity 1700W
* Mixed mode
SPECIAL ASPECTS IN THE MIXED MODE
Interruption of the power supply 230v
Combi Gas: The heater automatically switches
to the gas mode. As soon as the 230v power
supply is connected, the heater automatically
switches back to the mixed mode.
MALFUNCTION IN THE COMBUSTION PROCESS
(E.G. LACK OF FUEL)
Combi Gas: The heater automatically switches
to the electro mode. If the heater should
operate in the mixed mode again, the cause of
the malfunction needs to be rectified. Switch
the heater off and on again on the control
panel.
1. Use the control knob/push button to
select the fan icon.
2. Click to change to the setting level.
3. Use the control knob/push button to
select the required fan level.
4. Click the control knob/push button to
confirm the value.
1. Use the control knob/push button to select
the timer symbol in the bottom corner.
2. Click to change to the setting level.
If the timer is activated (ON), the timer in the
menu is shown as deactivated (OFF).
Enter start time
3. Use the control knob/push button to set the
hours, then the minutes.
Enter end time point
4. Use the control knob/push button to set the
hours, then the minutes.
5. If the start time has passed when entered
the operating parameters are only taken into
consideration when the next start/end times
are reached.