7-38 VS1MD AC Drive User Manual
F60 Stall prevention level
Range: 30-200 [%]
Default: 150
Access Configurable
See Also: P32, F59
This parameter sets the amount of current to activate stall prevention during
acceleration, constant run or deceleration. The value set is a percentage of
P32 – Motor Rated Current.
F63 Save Up/down frequency
Range: 0 -1
Default: 0
Access Configurable
See Also: t1-t8,F64
This parameter decides whether to save the specified frequency during
up/down operation. When 1 is selected, the up/down frequency is saved in
F64.
'&