www.balluff.com 17english
7
  Operating mode (continued)
7.10  Errors and warnings
If an error occurs, a flashing error message is output on 
the display. The error message disappears once the error 
is eliminated.
Error 
message
Possible cause Troubleshooting
E r r out p
Switching stage must 
carry an excessive 
current. Load is 
switched off or limited.
Connect a
permissible load
(see Technical 
Data on 
page19).
E r r i  npt
Sensor not connected / 
out of specification.
Check sensor 
connection / 
operate within the 
permissible 
switching 
distance.
Tab. 7-11:  Error messages
Feedback and warnings for advanced functions 
(during teach-in)
With advanced functions (teach functions), errorfree 
execution is indicated through a brief flashing of the value/
selection range and the calculated values are applied.
BAE SA-CS-026-YP-BP02 / BAE SA-CS-026-YP-BP00,3-GS04
Comfort Sensor Amplifier