Operating mode (continued)
7.10 Errors and warnings
If an error occurs, a flashing error message is output on
the display. The error message disappears once the error
is eliminated.
Error
message
Possible cause Troubleshooting
E r r out p
Switching stage must
carry an excessive
current. Load is
switched off or limited.
Connect a
permissible load
(see Technical
Data on
page19).
E r r i npt
Sensor not connected /
out of specification.
Check sensor
connection /
operate within the
permissible
switching
distance.
Tab. 7-11: Error messages
Feedback and warnings for advanced functions
(during teach-in)
With advanced functions (teach functions), errorfree
execution is indicated through a brief flashing of the value/
selection range and the calculated values are applied.
BAE SA-CS-026-YP-BP02 / BAE SA-CS-026-YP-BP00,3-GS04