Balluff Network Interface / IO-Link BNI IOL-719-002-Z012
www.balluff.com
20
4 IO-Link Interface
4.4. Parameter data
/ Request data
DPP
ISDU
Object name
Length
Range
Default value
Index
Index
Sub-
Index
Identification data
07
hex
Vendor ID
2 bytes
read only
0378
hex
08
hex
09
hex
Device ID
3 bytes
050204
hex
0A
hex
0B
hex
10
hex
0
Vendor name
7 bytes
BALLUFF
11
hex
0
Vendor text
15 bytes
www.balluff.com
12
hex
0
Product name
20 bytes
BNI IOL-719-002-Z012
13
hex
0
Product ID
7 bytes
BNI00AJ
14
hex
0
Product text
32 bytes
Sensorhub Analog, 8
Analog Input
15
hex
0
Serial Nr
16 bytes
16
hex
0
Hardware Revision
1 byte
17
hex
0
Firmware Revision
18
hex
0
Application specific
tag
32 bytes
Parameter data
54
hex
0
Serial number
16 bytes
16x 00
hex
59
hex
0
Process data
alignment
1 byte
0..1
1
F0
hex
0
1-8
Analog mode
8 bytes
0
hex
-A
hex
,
FF
hex
FF
hex
F1
hex
0
1-8
Resolution
8 bytes
0..3
0
F2
hex
0
1-8
Pin assignment
8 bytes
0..3
1
F3
hex
0
1-8
Pt100/ Pt1000 mode
8 bytes
0..3
3
F4
hex
0
Wirebreak detection
enable
1 byte
0..1
0
F5
hex
0
1-8
Process data format
8 bytes
0..2
0
F6
hex
0
1-8
Switch Point 1
16 bytes
0
hex
-
FFFF
hex
0
F7
hex
0
1-8
Switch Point 2
16 bytes
0
hex
-
FFFF
hex
0
F8
hex
0
1-16
Switch Point Enable
2 bytes
0
hex
-
FFFF
hex
0
F9
hex
0
1-8
Thermocouple
grounding
8 bytes
0
hex