Balluff Network Interface / IO-Link BNI IOL-719-002-Z012
www.balluff.com
8
3 Getting Started
3.5. Sensor Interface
Standard I/O-port (M12, A-coded, female)
Pin
Voltage / Current input
1
+24 V, 150 mA (sensor supply)
2
Voltage / current input
3
GND (sensor supply, measurement)
4
Voltage / current input
5
-
Pin
Pt100, Pt1000 2 wire
1
Current Source 1 - / Analog In -
2
Current Source 1 - / Analog In -
3
Current Source 1 + / Analog In +
4
Current Source 1 + / Analog In +
5
-
Pin
Pt100, Pt1000 3 wire
1
Current Source -
2
Current Source 2 + / Analog In -
3
4
Current Source 1 + / Analog In +
5
-
Pin
Pt100, Pt1000 4 wire
1
Current Source -
2
Analog In -
3
Analog In +
4
Current Source +
5
-
Pin
Thermocouple Typ J, Typ K
1
-
2
Thermocouple +
3
Thermocouple -
4
-
5
-
Note
The +24V supply voltage is short circuit protected. The supply voltage will be
switched off in case of short circuit, in order to reduce the power dissipation. The
short circuit error is latched and it can be reset with the output process data.
Note
In case of current input, the BNI IOL-719-002-Z012 works only with 3-wire
sensors.