Product Type | I/O Module |
---|---|
Manufacturer | Balluff |
Model | BNI00E7 |
Communication Protocol | IO-Link |
Number of Inputs | 8 |
Number of Outputs | 4 |
Supply Voltage | 24 V DC |
Rated Operating Voltage Ue DC | 24 V DC |
Rated Operating Current Ie per Output | 0.5 A |
Short-Circuit Protection | Yes |
Protection Type IEC 60529 | IP67 |
Protection Class | III |
Connection | M12 |
Input Type | PNP, Type 3 in accordance with IEC 61131-2 |
Output Type | PNP, Type 3 in accordance with IEC 61131-2 |
Defines the primary purpose of the BNI CIB-Module as an I/O or IO-Link module.
Outlines requirements and precautions for installation and initial operation by trained personnel.
Covers important safety precautions, authorized personnel, and owner/operator obligations.
Explains the wiring for supply voltage and voltage output using pin diagrams.
Details the connection specifics for the CC-Link IE Field Basic network.
Details the procedure for resetting the module to its factory default settings.
Explains how to configure network parameters using engineering software like GxWorks3.
Describes integrating stations and using the DetectNow function in the configuration tool.
Details the pin assignments and process data mapping for module ports.
Lists the register assignments for Slave Master (RX) and Master Slave (RY) data.
Maps word registers (RWr/RWw) to process data based on station count.
Explains the meaning of bits in the module status area registers.
Describes how byte swapping affects process data representation.
Details the module's startup procedure and initialization mechanism.
Describes how errors and warnings are indicated and managed.
Explains the functionality for validating IO-Link device installations.
Lists error codes encountered during parameter processing and their meanings.
Explains the status and error indication provided by module LEDs.
Provides a detailed list of error codes and their classifications/procedures.