19
7 Cyclical transmission
Word range
RWr and RWw
Depending on the number of configured stations the process data mapping differs in the word
range.
2 assigned
stations
(8 bytes per
channel)
Register
Slave Master
Register
Master Slave
RWrm00
h
RWrm03
h
Status Area
RWwm00
h
RWwm03
h
Operation Area
RWrm04
h
RWrm07
h
Input process data
IO-Link port 0
RWwm04
h
RWwm07
h
Output process data
IO-Link port 0
RWrm08
h
RWrm0B
h
Input process data
IO-Link port 1
RWwm08
h
RWwm0B
h
Output process data
IO-Link port 1
RWrm0C
h
RWrm0F
h
Input process data
IO-Link port 2
RWwm0C
h
RWwm0F
h
Output process data
IO-Link port 2
RWrm10
h
RWrm13
h
Input process data
IO-Link port 3
RWwm10
h
RWwm13
h
Output process data
IO-Link port 3
RWrm14
h
RWrm17
h
Input process data
IO-Link port 4
RWwm14
h
RWwm17
h
Output process data
IO-Link port 4
RWrm18
h
RWrm1B
h
Input process data
IO-Link port 5
RWwm18
h
RWwm1B
h
Output process data
IO-Link port 5
RWrm1C
h
RWrm1F
h
Input process data
IO-Link port 6
RWwm1C
h
RWwm1F
h
Output process data
IO-Link port 6
RWr(m+1)00
h
RWr(m+1)03
h
Input process data
IO-Link port 7
RWw(m+1)00
h
RWw(m+1)03
h
Output process data
IO-Link port 7
m = assigned module station number
3 assigned
stations
(16 bytes per
channel)
Register
Slave Master
Register
Master Slave
RWrm00
h
RWrm03
h
Status Area
RWwm00
h
RWwm03
h
Operation Area
RWrm04
h
RWrm0B
h
Input process data
IO-Link port 0
RWwm04
h
RWwm0B
h
Output process data
IO-Link port 0
RWrm0C
h
RWrm13
h
Input process data
IO-Link port 1
RWwm0C
h
RWwm13
h
Output process data
IO-Link port 1
RWrm14
h
RWrm1B
h
Input process data
IO-Link port 2
RWwm14
h
RWwm1B
h
Output process data
IO-Link port 2
RWrm1C
h
RWr(m+1)03
h
Input process data
IO-Link port 3
RWwm1C
h
RWw(m+1)03
h
Output process data
IO-Link port 3
RWr(m+1)04
h
RWr(m+1)0B
h
Input process data
IO-Link port 4
RWw(m+1)04
h
RWw(m+1)0B
h
Output process data
IO-Link port 4
RWr(m+1)0C
h
RWr(m+1)13
h
Input process data
IO-Link port 5
RWw(m+1)0C
h
RWw(m+1)13
h
Output process data
IO-Link port 5
RWr(m+1)14
h
RWr(m+1)1B
h
Input process data
IO-Link port 6
RWw(m+1)14
h
RWw(m+1)1B
h
Output process data
IO-Link port 6
RWr(m+1)1C
h
RWr(m+2)03
h
Input process data
IO-Link port 7
RWw(m+1)1C
h
RWw(m+2)03
h
Output process data
IO-Link port 7
m = assigned module station number