EasyManuals Logo

Balluff BNI00E7 User Manual

Balluff BNI00E7
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
www.balluff.com
19
7 Cyclical transmission
Word range
RWr and RWw
Depending on the number of configured stations the process data mapping differs in the word
range.
2 assigned
stations
(8 bytes per
channel)
Register
Slave Master
Register
Master Slave
RWrm00
h
RWrm03
h
Status Area
RWwm00
h
RWwm03
h
Operation Area
RWrm04
h
RWrm07
h
Input process data
IO-Link port 0
RWwm04
h
RWwm07
h
Output process data
IO-Link port 0
RWrm08
h
RWrm0B
h
Input process data
IO-Link port 1
RWwm08
h
RWwm0B
h
Output process data
IO-Link port 1
RWrm0C
h
RWrm0F
h
Input process data
IO-Link port 2
RWwm0C
h
RWwm0F
h
Output process data
IO-Link port 2
RWrm10
h
RWrm13
h
Input process data
IO-Link port 3
RWwm10
h
RWwm13
h
Output process data
IO-Link port 3
RWrm14
h
RWrm17
h
Input process data
IO-Link port 4
RWwm14
h
RWwm17
h
Output process data
IO-Link port 4
RWrm18
h
RWrm1B
h
Input process data
IO-Link port 5
RWwm18
h
RWwm1B
h
Output process data
IO-Link port 5
RWrm1C
h
RWrm1F
h
Input process data
IO-Link port 6
RWwm1C
h
RWwm1F
h
Output process data
IO-Link port 6
RWr(m+1)00
h
RWr(m+1)03
h
Input process data
IO-Link port 7
RWw(m+1)00
h
RWw(m+1)03
h
Output process data
IO-Link port 7
m = assigned module station number
3 assigned
stations
(16 bytes per
channel)
Register
Slave Master
Register
Master Slave
RWrm00
h
RWrm03
h
Status Area
RWwm00
h
RWwm03
h
Operation Area
RWrm04
h
RWrm0B
h
Input process data
IO-Link port 0
RWwm04
h
RWwm0B
h
Output process data
IO-Link port 0
RWrm0C
h
RWrm13
h
Input process data
IO-Link port 1
RWwm0C
h
RWwm13
h
Output process data
IO-Link port 1
RWrm14
h
RWrm1B
h
Input process data
IO-Link port 2
RWwm14
h
RWwm1B
h
Output process data
IO-Link port 2
RWrm1C
h
RWr(m+1)03
h
Input process data
IO-Link port 3
RWwm1C
h
RWw(m+1)03
h
Output process data
IO-Link port 3
RWr(m+1)04
h
RWr(m+1)0B
h
Input process data
IO-Link port 4
RWw(m+1)04
h
RWw(m+1)0B
h
Output process data
IO-Link port 4
RWr(m+1)0C
h
RWr(m+1)13
h
Input process data
IO-Link port 5
RWw(m+1)0C
h
RWw(m+1)13
h
Output process data
IO-Link port 5
RWr(m+1)14
h
RWr(m+1)1B
h
Input process data
IO-Link port 6
RWw(m+1)14
h
RWw(m+1)1B
h
Output process data
IO-Link port 6
RWr(m+1)1C
h
RWr(m+2)03
h
Input process data
IO-Link port 7
RWw(m+1)1C
h
RWw(m+2)03
h
Output process data
IO-Link port 7
m = assigned module station number