Smart Pro installation instructions
NOTE: If unhappy with the speed or travel limit setting, restart
this procedure by resetting the door limit positions as per
below rst.
12.2 Clearing the Door Limit Positions
Limit positions can be deleted by:
a. Press the MODE button repetitively until the GEAR
LED
is lit.
b. Press and hold the MODE button for 10 secs, let the MODE
button go when the beeper stops and main light stops
ashing.
c. The close LED will ash continuously to indicate limits have
been cleared.
NOTE: If no action is taken within 30 seconds, the opener will
return to normal operating mode and restore the original
settings.
d. Follow from CLOSE limit: above to set new limit positions,
remembering to reset the tracklock.
12.3 Re-proling the Door
Re-proling is a simplied way of re-learning the travel
characteristic of a previously setup Limit Switch travel
installation. Re-proling can be used when the travel
characteristics of the door change due to mechanical
adjustments etc. To initiate a re-prole:
a. Limits must be set.
b. Press the MODE button repetitively until the GEAR
LED
is lit.
c. Press and hold the CLOSE button
for two seconds, the
door will open and close by itself to record prole.
12.4 Controller memory reset
To clear the controller by:
a. Pressing and holding MODE button for 10secs while in
limit set mode will cause all control memory to be set to
factory defaults.
b. This excludes transmitters, history log and cycle counters.
If limits are already set, clear limits rst by using 12.2
Clearing the door limit positions and then clear
controller via 12.4 Controller memory reset.