EasyManuals Logo

Banner DF-G1-NS-2M Installation Guide

Banner DF-G1-NS-2M
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Guide
Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies.
For complete technical information about this product, including dimensions, accessories, and specifications, see
Banner Engineering website.
Overview
Figure 1. DF-G1 Model Features
1 Output LED
2 LO/DO Switch
3 RUN/PRG/ADJ Mode Switch
4 Lever Action Fiber Clamp
5 Red Signal Level
6 Green Threshold
7 +/SET/- Rocker Button
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Models
Model Outputs Connector
1
DF-G1-NS-2M Single NPN
2 m (6.5 ft) cable, 4-wire
DF-G1-PS-2M Single PNP
DF-G1-KS-2M Dual outputs, 1 push-pull IO-Link and 1
PNP (complementary outputs)
DF-G1-NS-Q5 Single NPN
150 mm (6 in) PVC pigtail, M12 Euro QD connector,
4-pin
DF-G1-PS-Q5 Single PNP
DF-G1-KS-Q5 Dual outputs, 1 push-pull IO-Link and 1
PNP (complementary outputs)
DF-G1-NS-Q7 Single NPN
Integral M8 Pico QD connector, 4-pin
DF-G1-PS-Q7 Single PNP
DF-G1-KS-Q7
Dual outputs, 1 push-pull IO-Link and 1
PNP (complementary outputs)
1
Connector options:
A model with a QD connector requires a mating cordset .
For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M
).
For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NS-Q3).
DF-G1 Expert
Dual Display Fiber Amplifier
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Other manuals for Banner DF-G1-NS-2M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Banner DF-G1-NS-2M and is the answer not in the manual?

Banner DF-G1-NS-2M Specifications

Power IconPower
supply voltage10 to 30 V dc
power consumption (standard display mode)960 mW
current consumption (standard display mode)< 40 mA at 24 V dc
power consumption (ECO display mode)720 mW
current consumption (ECO display mode)< 30 mA at 24 V dc
Output IconOutput
output configuration1 current sinking (NPN) or 1 current sourcing (PNP) output
output rating100 mA max. load
off-state leakage current (NPN/PNP models)< 5 μA at 30 V dc
on-state saturation voltage (NPN)< 1.5 V
Performance IconPerformance
output response time (high speed)200 µs
output response time (standard)500 µs
repeatability (high speed)66 µs
repeatability (standard/long range/extra long range)100 µs
Operating Environment IconOperating Environment
operating temperature−10 °C to +55 °C
storage temperature−20 °C to +85 °C
humidity90% at +60 °C maximum relative humidity (non-condensing)