EasyManua.ls Logo

Banner SX5-B - Page 106

Banner SX5-B
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Icon Fault Code Device Status
OSSD
Status
Description
MUTING
ERR
Normal On Muting has not activated because the correct sequence was not followed.
MUTING Normal On
The Muting function is active.
If a Mute Lamp output is configured, it should be flashing.
OVERRIDE
ERR
Normal On
Override has not been activated because the correct sequence has not
been followed or there are no override conditions.
OVERRIDE Normal On The Override function is active.
OVERTEMP Normal On
The unit is operating above or below its allowed operating temperature
range. Restore the proper ambient temperature to ensure proper operation
of the scanner.
OVR
TIMEOUT
Normal On The Override timeout function has expired.
!
HIGH REFL-BKG
HIGH REFL-
BKG
Normal On
A high reflecting background is detected that could affect detection
capability. Reduce or remove the reflecting background. (See Light
Interference on p. 30 and Highly Reflective Backgrounds on p. 30.)
!
CHECK MASTER
CHECK
MASTER
Normal On
The remote unit is fine, but is reporting a problem with the master scanner.
Check the master unit.
!
WINDOW REPLACE
WINDOW
REPLACE
Normal Off Window replacement procedure is in progress
SX Safety Laser Scanner
106 www.bannerengineering.com - Tel: + 1 888 373 6767

Table of Contents

Related product manuals