7 Operating Instructions
7.1 Status Indicators
The SX has three buttons, a graphical display, and five status LEDs (located below the display).
The SX has diagnostic LEDs for initial diagnostics. The OFF state and ON state LEDs are below the scanner's display. When
it is not possible to see the display because of the way it was mounted or because it is hidden from the operator's position,
use the software's Monitoring function to check the status.
Symbol Meaning
Figure 72. Status LEDs
1 2 3 4 5
LED 1: Object Detection in Safety Zone (OSSD 11/12)
Red—Object detected in the Safety Zone
Green—No object is detected in the Safety Zone
LED 2: not available
LED3: Assigned to Warning Zone 2
Amber—Object detected in Warning Zone 2
OFF—No object detected in Warning Zone 2
LED 4: Assigned to Warning Zone 1
Amber—Object detected in Warning Zone 1
Off—No object detected in Warning Zone 1
LED 5: Interlock
Amber—Interlock function active (waiting for a restart signal)
Button 1: to browse quickly the Menu functions (up)
Button 2: to enter and confirm the selected function
Button 3: to browse quickly the Menu functions (down)
7.2 Display Menu
To enter the Display menu, push the square button. The display supplies information about the status of the scanner and for
diagnostics and troubleshooting. The menu is divided into three main areas (Information, Settings, and Exit). Use the up and
down arrow buttons to browse the menu structure.
Information—Accesses the hardware and configuration options
Settings—Accesses Display Settings and Reset options
Exit—Select Exit and push the square button to exit the menu option
7.3 Resetting the System
Perform system resets and scanner restarts using an external reset switch. If supervisory control of the reset/restart switch is
required, a key switch may be used, with the key kept in the possession of a Designated or Qualified Person.
Using a key switch will also provide some level of personal control, since the key may be removed from the switch. This will
hinder a reset/restart while the key is under the control of an individual, but must not be relied upon solely to guard against
accidental or unauthorized reset. (Spare keys in the possession of others or additional personnel entering the safeguarded
area unnoticed may create a hazardous situation.)
Any Multi-in or Multi-in/out pin can be configured as a reset/restart input if needed in a configuration.