Resolution and Range
Models Resolution (mm) Max. Range (m)
SX5
30 2.5
40 3.0
50 4.0
70 5.5
150 5.5
Safety Data
Type 3 (EN 61496-1)
SIL 2 (IEC 61508)
Category 3 (EN ISO 13849-1)
SILCL 2 (EN 62061)
PL d (EN ISO 13849-1)
PFHd (mean probability of a dangerous failure per hour): 6.38 × 10
-8
SFF: 97.58%
MTTFd: 61 Years
TM (mission time): 20 years (EN ISO 13849-1)
HFT (Hardware Fault Tolerance): 1
State of safety: OSSD in OFF State (open circuit → I OSSD = 0)
Response time to malfunction:
≤ Response Time
Features
Warning field range:
8 m (typical) for flat black 1.8% target
22 m (typical) for flat gray 18% target
40 m (typical) for flat white 90% target
50 m (typical) for flat reflecting target
Scanning angle: 275°
Detection capability: 30/40/50/70/150 mm selectable
Scan cycle time: 30 ms
Response time: Programmable from 62 to 1202 ms (482 ms for the SX5-
B model)
Network Latency Time (Master/Remote models): 10 ms for each
connected remote unit (1 remote unit adds 10 ms to response time, 2
remote units adds 20 ms to the response time and 3 remote units adds
30 ms response time)
Tolerance zone max: 150 mm
Angular resolution: 0.1°
Maximum number of Zones sets:
Stand-alone model: 6
8-pin master model: 3
12-pin master model: 10
17-pin master model: 20
17+8 pin master model: 70
Maximum number of Warning Zones: 2
Maximum number of OSSD pairs: 3
Supplement for retro-reflectors on scan plane in front of a safety zone:
200 mm (see Highly Reflective Backgrounds on p. 30)
Supplement for high ambient light within ± 5° of scan plan: 200 mm (see
Light Interference on p. 30)
Deviation from ideal flatness of scan field at max safety range: < 5 cm
Distance between center point of scan plane and top edge of housing:
37.7 mm
Distance of mirror rotational axis (zero point of x and y axis) to rear side
of housing: 52.5 mm
Operating Conditions
–10 °C to +50 °C (+14 °F to +122 °F)
7
95% maximum relative humidity (non-condensing)
(According to IEC
61496-1 5.4.2; IEC 61496-3 5.4.2; 4.3.1; 5.4.4.3)
Storage Conditions
–20 °C to +70 °C (–4 °F to +158 °F)
Shock
According to IEC 61496-1 4.3.3.2 ; 5.4.4.2
IEC 60068-2-29; Acceleration: 10 g; Pulse Duration: 16 ms; Number of
Shocks: 1000 ± 10 (for each of the three mutually perpendicular axes)
IEC 61496-3 5.4.4.1-3 ; IEC 60068-2-75 ; Hammer test
Vibration
According to IEC 61496-1 4.3.3.1 ; 5.4.4.1 ; IEC 60068-2-6
Frequency from 10 Hz to 55 Hz ; Scan Speed 1 octave/min
Range: 0.35 mm ± 0.05 mm
Environmental Rating
IEC IP65
Certifications
AOPDDR
5KE3
7
We recommend that you allow for a 15-minute warmup from a cold start.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767 23