Type Function Description Circuit
AREA SWITCH 5
Muting Enable 1
If high the muting feature is enabled and is
allowed to be performed
Muting 11 Initiate the muting function if
Muting 12 engaged with the proper timing
EDM 1 External Device monitoring input for Need circuit with 2
EDM 2 OSSD 1 and/or OSSD 2 NC contacts to 24 V
Override (single line
pattern)
Forces scanner OSSDs on
Multi out
Muting Lamp 1
Active muting function signal, supplies 24
VDC to LED lamp
Warning 1
Output to signal an interruption of a warning
field
Warning 2
Alarm 1 Clean window (CLEANW2 code)
Alarm 2 Scanner fault (OSSDs off)
Alarm 3 Override on
Safety Output
OSSD 2/1
OSSD 2/2
No Function Not used
Note: The second set of OSSDs are aligned to the main outputs OSSD1/1 and OSSD1/2 (which are not
configurable) requirements. When a Multi Out pin is selected, a second pin will automatically be configured
(per IEC 61496 requirements). This ensures that two Multi Out outputs are used for the same purpose.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767 57