EasyManua.ls Logo

Banner SX5-B - Page 57

Banner SX5-B
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Type Function Description Circuit
AREA SWITCH 5
Muting Enable 1
If high the muting feature is enabled and is
allowed to be performed
+24 V DC
Muting 11 Initiate the muting function if
+24 V DC
Muting 12 engaged with the proper timing
EDM 1 External Device monitoring input for Need circuit with 2
EDM 2 OSSD 1 and/or OSSD 2 NC contacts to 24 V
Override (single line
pattern)
Forces scanner OSSDs on
+24 V DC
Multi out
Muting Lamp 1
Active muting function signal, supplies 24
VDC to LED lamp
0 V
Warning 1
Output to signal an interruption of a warning
field
0 V
PNP
Warning 2
Alarm 1 Clean window (CLEANW2 code)
0 V
PNP
Alarm 2 Scanner fault (OSSDs off)
Alarm 3 Override on
Safety Output
OSSD 2/1
0 V
PNP
OSSD 2/2
No Function Not used
Note: The second set of OSSDs are aligned to the main outputs OSSD1/1 and OSSD1/2 (which are not
configurable) requirements. When a Multi Out pin is selected, a second pin will automatically be configured
(per IEC 61496 requirements). This ensures that two Multi Out outputs are used for the same purpose.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767 57

Table of Contents

Related product manuals