WARNING:
• Properly install arc or transient suppressors
•
Failure to follow these instructions could result in serious injury or death.
• Install any suppressors as shown across the coils of the machine primary control elements. Do not
install suppressors directly across the output contacts of the safety or interface module. In such a
configuration, it is possible for suppressors to fail as a short circuit.
Figure 44. Generic 12-pin wiring to an FSD
+24 V DC 0 V DC
OSSD 1/1
OSSD 1/2
Restart
EDM1
FSD2
FSD1
Single-Channel
Safety Stop
Circuit
Dual-Channel
Safety Stop
Circuit
4 - Green
12 - Red/Blue
5 - Pink
8 - Gray
7 - Black *
9 - Red *
10 - Violet *
11 - Gray/Pink *
3 - White *
+24 V DC
1 - Brown
6 - Yellow 0 V DC
2 - Blue 0 V DC
+24 V DC
Functional Earth
Scanner
12-pin
Male M12
* Functionality of pins 3, 7, 9, 10
and 1
1 is configured with the GUI
Monitoring FSDs-FSDs must be
monitored for proper
operation
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767 59