Type Function Description Circuit
Multi in
RESTART 1 Restarts the device following OSSD 1 off-status
RESTART 2 Restarts the device following OSSD 2 off-status
RESET
Restores the device after a fault condition (like a power
cycle)
RESTART 1/RESET
Restarts or restores the device
RESTART 2/RESET
RESTART 1/RESET/EDM 1
Restarts or restores the device, and performs external
device monitoring function
RESTART 2/RESET/EDM 2
SHUT OFF Enables the shut off function
AREA SWITCH 1
Switches the detection areas by employing external
signals
AREA SWITCH 2
AREA SWITCH 3
AREA SWITCH 4
AREA SWITCH 5
AREA SWITCH 6
AREA SWITCH 7
AREA SWITCH 8
Muting Enable 1
If high the muting feature is enabled and is allowed to be
performed
Muting Enable 2
Muting 11
Initiate the muting function if engaged with the proper
timing
Muting 12
Muting 21
Muting 22
Override 11 (Pulsed)
Forces appropriate OSSD outputs on (either pulsed signal
or level input)
Override 11 (Level)
Override 12 (Level)
Override 21 (Pulsed)
Override 21 (Level)
Override 22 (Level)
EDM 1 External Device monitoring input for Need circuit with 2
EDM 2 OSSD 1 and/or OSSD 2 NC contacts to 24 V
Multi in High
Speed
Encoder 11
Enables the encoder function ; Both couples are
automatically activated
Encoder 12
Encoder 21
Encoder 22
Multi out
Muting Lamp 1
Active muting function signal, supplies 24 V DC to LED
lamp
Muting Lamp 2
Warning 1
Output to signal an interruption of a warning field
Warning 2
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767 61