Configuration through web interface– 71
Enable/disable:Enable/disable the additional alert on alarm triggering on the internal monitor
using the SIP protocol. Notification occurs by sending SIP messages to the specified SIP number
on which the BAS-IP Intercom application is installed.
Main number: Input field for the first SIP number to which the alarm will be sent.
Second number:Input field for the second SIP number to which the alarm will be sent.
Delay: Delay before sending SIP messages when an alarm is triggered.
Auto call: Enable / disable additional alert on alarm triggering on the internal monitor via SIP
protocol. Notification occurs by calling the specified SIP number on which the BAS-IP Intercom
application is installed.
Number: SIP number input field for automatic call when an alarm is triggered.
Heartbeat: Enable/disable the additional alert on alarm triggering on the internal monitor via SIP protocol.
Notification occurs by sending SIP messages to the specified SIP number on which the BAS-IP Intercom
application is installed for the specified interval in seconds.
Data: A message input field that will be sent at a specified time interval.
Timeout: SIP message sending interval in seconds.