AW00097209000 Configuring the Camera
Basler IP Fixed Box Cameras 43
Motion Tab
Cyclic Tab
Heartbeat Missing Tab
Source Enable - Check the Source Enable box on the Motion tab to
enable motion detection as a source for declaring an alarm
condition.
If motion detection is enabled as an alarm source and motion is
detected, an alarm condition will be declared.
(In order to use motion detection as an alarm source, motion
detection must be enabled. See Section 3.5 on page 40 for more
information about motion detection.)
Source Enable - Check the Source Enable box on the Cyclic tab to
enable the cyclic alarm source for declaring recurrent alarm
conditions.
A recurrent alarm will be declared after a certain time, that is to be
configured in Period of Time [s], has expired.
Period of Time [s] - Sets the time in seconds between two alarm
conditions that must expire before a recurrent alarm is declared.
Source Enable - Check the Source Enable box on the
Heartbeat Missing tab to enable the heartbeat missing alarm source
for declaring an alarm condition when the heartbeat timeout expires.
Note that the camera’s SNMP agent has to be enabled for using the
heartbeat missing alarm source (see page 56).
For basic information on SNMP and the heartbeat functionality, see
the description of the SNMP tab on page 56.