AW00097209000 The Terminal Connector
Basler IP Fixed Box Cameras 87
Fig. 11: I/O Schematic, Variant 1 (Input Port Connected to Ground via Switch)
Gnd
Alt. Camera Power
RS-485 B-
RS-485 A+
5
2
3
8
1
6
+24
VDC
Max
Switch
Device
RS-485 Gnd
RS-485 A+
RS-485 B-
Camera
+5
VDC
1 k
+5
VDC
1 k
I/O-2
(Set as an output)
(Set as an output)
I/O-1
4
I/O-0
+5
VDC
1 k
(Set as an input)
7
DC Out
+5
VDC
+12 to +24
VDC
5
1
Device
RS-485 Gnd
RS-485 A+
RS-485 B-
7
Gnd
RS-485 B-
RS-485 A+
Fig. 12: I/O Schematic, Variant 2 (Input Port Connected to Input Voltage)
0 to +24 VDC
+5
VDC
1 k
(Set as an input)
I/O-2
8