9440300990 29-23
DECS-250 PROFIBUS Communication
Instance Name
Inst. #
Type
RW
Key Name
Unit
Range
OEL Takeover
112
Float
R/W
OEL Sec Takeover
Time Dial On GG
No Unit
0.1 - 20
UEL Configure
113
UINT32
R/W
Sys Option Input
UEL Enabled GG
No Unit
Disabled=0 Enabled=1
UEL Configure
114
Float
R/W
UEL Pri Pow Filter TC GG
Sec
0 - 20
UEL Configure
114
Float
R/W
UEL Pri Volt Dep
Exponent GG
No Unit
0 - 2
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve X1 GG
KW
0 - 62
UEL Curve Float Primary
116
Float
R/W
Uel Pri Curve X2 GG
KW
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve X3 GG
KW
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve X4 GG
KW
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve X5 GG
KW
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve Y1 GG
kvar
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve Y2 GG
kvar
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve Y3 GG
kvar
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve Y4 GG
kvar
0 - 62
UEL Curve Float Primary
116
Float
R/W
UEL Pri Curve Y5 GG
kvar
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve X1 GG
KW
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve X2 GG
KW
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve X3 GG
KW
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve X4 GG
KW
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve X5 GG
KW
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve Y1 GG
kvar
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve Y2 GG
kvar
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve Y3 GG
kvar
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve Y4 GG
kvar
0 - 62
UEL Curve Float Secondary
118
Float
R/W
UEL Sec Curve Y5 GG
kvar
0 - 62
SCL Settings
119
UINT32
R/W
Sys Option Input SCL
Enabled GG
No Unit
Disabled=0 Enabled=1
SCL Settings
120
Float
R/W
SCL Pri Ref Hi GG
Amp
0 - 66000
SCL Settings
120
Float
R/W
SCL Pri Ref Lo GG
Amp
0 - 66000
SCL Settings
120
Float
R/W
SCL Pri Time Hi GG
Sec
0 - 60
SCL Settings
120
Float
R/W
SCL Pri No Response
Time GG
Sec
0 - 10
SCL Settings
120
Float
R/W
SCL Sec Ref Hi GG
Amp
0 - 66000
SCL Settings
120
Float
R/W
SCL Sec Ref Lo GG
Amp
0 - 66000
SCL Settings
120
Float
R/W
SCL Sec Time Hi GG
Sec
0 - 60
SCL Settings
120
Float
R/W
SCL Sec No Response
Time GG
Sec
0 - 10
SCL Settings
120
Float
R/W
Reserved
n/a
n/a
SCL Settings
120
Float
R/W
Reserved
n/a
n/a
SCL Settings
120
Float
R/W
Reserved
n/a
n/a
SCL Settings
120
Float
R/W
Reserved
n/a
n/a
SCL Settings
120
Float
R/W
Reserved
n/a
n/a
VAR Limiter Settings
121
UINT32
R/W
Var Limit Enable GG
No Unit
Disabled=0 Enabled=1
VAR Limiter Settings
122
Float
R/W
Var Limit Pri Delay GG
Sec
0 - 300
VAR Limiter Settings
122
Float
R/W
Var Limit Pri
Setpoint GG
%
0 - 200
VAR Limiter Settings
122
Float
R/W
Var Limit Sec Delay GG
Sec
0 - 300
VAR Limiter Settings
122
Float
R/W
Var Limit Sec
Setpoint GG
%
0 - 200