EasyManua.ls Logo

Bauer Junior II-W - B-Timer Operation; B-Timer Functional Display; Reset

Bauer Junior II-W
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fi
g
. 22
Instruction Manual Junior II
15
Operation
The B-Timer is activated when starting the
compressor. Compressor operation is indi
cated by the flashing “h” symbol.
To switch on the B-Timer press one of the keys on the display.
Main menue will be displayed (Fig. 16).
If no key is pressed within 1 minute, the in
dication will return to the main menue.
After 2 minutes the B-Timer is switched off,
if no compressor operation is detected.
Function Display
To display the desired function, press the se
lect key ().
Press key. Remaining filter capacity is shown, Fig. 17)
Press key again. Remaining operating hours to service inter
val A (500 hours or annually) are shown (Fig. 18).
Press key again. Remaining operating hours to service inter
val B (1000 hours or annually) are shown (Fig. 19).
Press key again. Remaining operating hours to service inter
val C (2000 hours or biennially) are shown (Fig. 20).
Press key. Filter cartrige number is shown (Filter symbol
flashing, Fig. 21).
Press key again. Display returns to the main menue.
Reset
The filter capacity must not be reset unless
a new filter cartridge has been fitted!
To reset the filter capacity or the A, B, and C maintenance in
tervals, press key for more than 5 seconds from the respect
ive maintenance interval display (Fig. 22).