Instruction Manual Junior II
22
1. Filter cartridge 057679: lifetime [hours]
Filling pressure p = 200 bar
Junior II
Ambient temperature
tU [°C]
Final separator temperature
tAb [°C]
Delivery
Q [l/min]
100
10 20 - 24 26 - 21
15 25 - 29 20 - 16
20 30 - 34 15 - 12
25 35 - 39 11 - 9
30 40 - 44 9 - 7
35 45 - 49 7 - 6
40 50 - 54 5 - 5
Filling pressure p = 300 bar
Junior II
Ambient temperature
tU [°C]
Final separator temperature
tAb [°C]
Delivery
Q [l/min]
100
10 20 - 24 39 - 31
15 25 - 29 29 - 24
20 30 - 34 22 - 18
25 35 - 39 17 - 14
30 40 - 44 13 - 11
35 45 - 49 10 - 9
40 50 - 54 8 - 7
Filter cartridge 057679: bottle fillings [number] Molecular sieve mass mMS [g] = 68
Ambient
temperature
tU [°C]
Final separa
tor tempera
ture
tAb [°C]
Air humidity,
saturated
X [g/m
3
]
Processable air volume Va
[m
3
]
at pressure p [bar]
Number of bottle fillings n
acc. to bottle size
200 300 7 l 10 l 12 l
10 20 - 24 17,31 - 21,80 157 - 125 236 - 187 112 - 89 79 - 62 65 - 52
15 25 - 29 23,07 - 28,79 118 - 94 177 - 142 84 - 67 59 - 47 49 - 39
20 30 - 34 30,40 - 37,63 89 - 72 134 - 108 64 - 52 45 - 36 37 - 30
25 35 - 39 39,65 - 48,64 69 - 56 103 - 84 49 - 40 34 - 28 29 - 23
30 40 - 44 51,21 - 62,41 53 - 44 80 - 65 38 - 31 27 - 22 22 - 18
35 45 - 49 65,52 - 79,28 42 - 34 62 - 51 30 - 25 21 - 17 17 - 14
40 50 - 54 83,08 - 99,85 33 - 27 49 - 41 23 - 19 16 - 14 14 - 11
Bottle volume VF [m
3
]
Bottle size at pressure p [bar]
l [ltr.] 200 300
7 1,4 2,1
10 2 3
12 2,4 3,6
Number of bottle fillings n=
processable air volume / bottle volume = Va / VF
Bottle volume: VF [m
3
] = p [bar] x l [l] / 1000 [l/m
3
]
Processable air volume: Va [m
3
] = 0,2 x mMS [g] / (X [g/m
3]
/
p [bar]) = 0,2 x p [bar] x mMS [g] / X [g/m
3
]
Filter cartridge lifetime: tp [h] = Va [m
3
] / (Q [m
3
/min] x 60
[min/h])