TA202
www.baumer.com
47
Measurement using the Time measurement is initiated by a pulse at the input „F2/start“ and
start and stop signal terminated by a pulse at the input „stop“. Both inputs respond to the
front pulse flank. F2 indicated a currently running measurement
process.
Period duration Time measurement is started by the front pulse flank at the input
„F2/Start“ and terminated with the subsequent front pulse flank.
The measurement process can be interrupted by means of the
„stop“ input (gate function). F2 indicates a currently running
measurement process.
Pulse duration Time measurement is started by the front pulse flank at the input
„F2/Start“ and terminated with rear pulse flank. The measurement
process can be interrupted by means of the „Stop“ input (gate
function). F2 indicates a currently running measurement process.
Pulse rate measurement The pulse rate measurement is started by the first pulse at the input
„F1/A“ and terminated after recognition of a pulse rate pause.
Standstill recognition automatically ensures an update of the display
following every pulse rate. The pause time between pulse rates is
programmed under „time out“ in line 29. Possible applications:
For forward feed display and monitoring on punching machines etc.
6 Technical data
Technical data - electrical ratings
Voltage supply 24/48 VAC ±10 % (50/60 Hz)
115/230 VAC ±10 % (50/60 Hz)
24 VDC ±10 %
Power consumption 7 VA, 5 W
Sensor supply 12...26 VDC / max. 100 mA
Display LED, 7-segment display
Number of digits 6-digits
Digit height 14 mm
Display unit 1/s, 1/min, 1/h programmable
Function Tachometer, ratio display
Measuring principle Period duration measurement
Calculating functions Difference F1-F2 Ratio F1:F2
Stretch-/shrinking (F2-F1):F1
Flow
Pulse rate measurement
Signal inputs Comparator inputs
Input logic NPN / PNP
Control inputs 2 Inputs
Control functions Start, Stop
Counting frequency F1: 10 kHz / F2: 25 Hz, 40 kHz
Scaling factor 0.0001...9999.99
Data memory >10 years in EEPROM
Outputs electronic Optocoupler