Product name iMPI V200
AWHP 4.5 MR
iMPI V200
AWHP 6 MR-3
iMPI V200
AWHP 8 MR-2
Brine-to-water heat pump No No No
Low-temperature heat pump No No No
Equipped with a supplementary heater Yes Yes Yes
Heat pump combination heater Yes Yes Yes
Rated heat output under average conditions
(1)
Prated
kW 4 4 6
Rated heat output under colder conditions
Prated
kW 5 4 6
Rated heat output under warmer conditions
Prated
kW 4 5 6
Declared capacity for heating for part load at an in
door temperature of 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW 3.8 3.5 5.6
T
j
= +2 °C
Pdh
kW 4.3 4.5 2.9
T
j
= +7 °C
Pdh
kW 4.5 4.8 6.4
T
j
= +12 °C
Pdh
kW 5.5 5.2 4.3
T
j
= bivalent temperature
Pdh
kW 3.9 3.6 5.2
T
j
= operation limit temperature
Pdh
kW 3.9 3.6 5.2
Bivalent temperature
T
biv
°C -10 -10 -10
Degradation coefficient
(2)
Cdh
— 1.0 1.0 1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
% 134 137 129
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
% 109 116 119
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
% 179 172 169
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
- 1.64 1.89 1.95
T
j
= +2 °C
COPd
- 3.46 3.53 3.22
T
j
= +7 °C
COPd
- 4.96 4.74 4.57
T
j
= +12 °C
COPd
- 7.90 7.08 6.55
T
j
= bivalent temperature
COPd
- 1.20 1.52 1.70
T
j
= operation limit temperature
COPd
- 1.20 1.52 1.70
Operation limit temperature for air-to-water heat
pumps
TOL
°C -10 -10 -10
Heating water operating limit temperature
WTOL
°C 55 60 60
Electrical power consumption
Off mode
P
OFF
kW 0.009 0.009 0.009
Thermostat-off mode
P
TO
kW 0.049 0.049 0.049
Stand-by
P
SB
kW 0.009 0.015 0.014
Crankcase heater mode
P
CK
kW 0.000 0.055 0.055
Supplementary heater
Rated heat output
Psup
kW 0.0 0.0 0.0
Type of energy input Electricity Electricity Electricity
Other specifications
Capacity control Variable Variable Variable
Sound power level, indoors - outdoors
L
WA
dB 49 – 61 49–65 49 – 67
Annual energy consumption under average con
ditions
Q
HE
kWh 2353 2124 3499
Annual energy consumption under colder condi
tions
Q
HE
kWh 4483 3721 4621
3 Technical specifications