Product name iMPI V200
AWHP 4.5 MR
iMPI V200
AWHP 6 MR-3
iMPI V200
AWHP 8 MR-2
Annual energy consumption under warmer condi
tions
Q
HE
kWh 1249 1492 1904
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2100 2100 3300
Declared load profile L L L
Daily electricity consumption
Q
elec
kWh 4.020 4.816 4.816
Annual electricity consumption
AEC
kWh 845 968 968
Water heating energy efficiency
ƞ
wh
% 121.00 106.00 106.00
Daily fuel consumption
Q
fuel
kWh 0.000 0.000 0.000
Annual fuel consumption
AFC
GJ 0 0 0
(1) The rated heat output
Prated
is equal to the design load for heating
Pdesignh
, and the rated heat output of a supplementary heater
Psup
is
equal to the supplementary capacity for heating
sup(Tj)
.
(2) If
Cdh
is not determined by measurement, the default degradation coefficient is
Cdh
= 0.9.
Tab.12 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name iMPI V200
AWHP 11 MR-2
AWHP 11 TR-2
iMPI V200
AWHP 16 MR-2
AWHP 16 TR-2
Air-to-water heat pump Yes Yes
Water-to-water heat pump No No
Brine-to-water heat pump No No
Low-temperature heat pump No No
Equipped with a supplementary heater Yes Yes
Heat pump combination heater Yes Yes
Rated heat output under average conditions
(1)
Prated
kW 6 9
Rated heat output under colder conditions
Prated
kW 4 7
Rated heat output under warmer conditions
Prated
kW 8 13
Declared capacity for heating for part load at an in
door temperature of 20 °C and outdoor tempera
ture
T
j
T
j
= -7 °C
Pdh
kW 5.9 9.0
T
j
= +2°C
Pdh
kW 5.3 6.5
T
j
= +7 °C
Pdh
kW 9.0 12.9
T
j
= +12 °C
Pdh
kW 7.7 10.0
T
j
= bivalent temperature
Pdh
kW 6.3 8.8
T
j
= operation limit temperature
Pdh
kW 6.3 8.8
Bivalent temperature
T
biv
°C -10 -10
Degradation coefficient
(2)
Cdh
— 1.0 1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
% 125 121
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
% 113 113
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
% 167 161
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
- 1.87 1.85
T
j
= +2 °C
COPd
- 3.17 3.02
T
j
= +7 °C
COPd
- 4.54 4.34
T
j
= +12 °C
COPd
- 6.19 5.75
T
j
= bivalent temperature
COPd
- 1.20 1.35
3 Technical specifications