37
INSTALLER Section (en)
7219620.01 (1-04/15)
P19 Manufacturer information 07
P20 Pump overrun time in DHW mode (seconds) 30
P21
00…54 55…67
(set the desired temperature value)
00
P22 Manufacturer information 00
P23 Maximum DHW setpoint temperature (ACS) 60
P24 Manufacturer information 35
P25 00
P26..P31 Manufacturer information --
P32..P41 Diagnostics (See SERVICE Instructions) --
P67
Open Therm (OT) settings (See SERVICE Instructions
)
00
00
14.1 ADJUSTING MAXIMUM HEATING POWER
parameter P13
To access and edit parameter P13 values, proceed as described in the PARAMETER SETTINGS section.
Boiler model - PARAMETER P13 (%) / Heating output (kW)
kW 1.12 1.24 1.28 24 28 33 40
2 0
3 10
3,5 15 0 0
4 20 2 0 2 0
5 30 7 4 7 4 0
6 40 12 8 12 8 4 0
7 50 17 13 17 13 7 3
8 60 22 17 22 17 11 6
9 70 27 21 27 21 14 9
10 80 32 25 32 25 18 11
12 100 41 33 41 33 25 17
14 51 42 51 42 32 23
16 61 50 61 50 39 29
18 71 58 71 58 46 34
20 80 67 80 67 54 40
22 90 75 75 61 46
24 100 83 86 68 51
26 92 75 57
28 100 80 63
30 69
32 74
33 77