INSTALLER Section (en)
15. TROUBLESHOOTING SERVICE FAULTS
and a number (fault code). For a complete list of faults, see the
If
Description of fault Service action
09
Gas valve connection error
electronic board.
10
Check the sensor (*).
12
13
See the actions indicated in E12
15
Gas valve control error
18
19
20
Check the sensor (**).
28
Check the fumes NTC probe (***).
40
See the actions indicated in E20
50
See the actions indicated in E20
53
Fumes outlet obstructed
Check that the drainage pipe is free from obstructions.
seconds.
55
Electronic board not calibrated
Activate the automatic calibration function described in the
spare parts instructions sheet.
83…87
board or RF link.
92
Fumes fault during calibration (probable fumes recirculation)
Activate the automatic calibration function described in
the paragraph YEARLY MAINTENANCE – REPLACING
COMPONENTS.
109
110
Check that the limit thermostat is undamaged and replace it if
117
See the FILLING THE SYSTEM section.
118
the FILLING THE SYSTEM section).
125
(control performed via a temperature sensor)
See the actions indicated in E109
128
POSITIONING THE ELECTRODES section).
See the actions indicated in E92
129
POSITIONING THE ELECTRODES section).
130
Fumes NTC tripped due to overtemperature
Check the fumes NTC probe (***).